Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38614278

RESUMO

PURPOSE: A novel form of lung function imaging has been developed that uses 4DCT data to generate lung ventilation images (4DCT-ventilation). Functional avoidance uses 4DCT-ventilation to reduce doses to functional lung with the aim of reducing pulmonary side-effects. A 4DCT-ventilation functional avoidance, phase II, multi-center clinical trial was completed. The purpose of this work is to quantify patient reported outcomes (PRO) changes for patients treated with functional avoidance and to determine which metrics are predictive of PRO changes. MATERIALS AND METHODS: Patients with locally advanced lung cancer receiving curative intent radiotherapy were accrued. Each patient had a 4DCT-ventilation image generated using 4DCT data and image processing. PRO instruments included the Functional Assessment of Cancer Therapy-Lung (FACT-L) questionnaire, administered pre-treatment, 3, 6, and 12 months post-treatment. FACT-TOI (Trial Outcome Index) and the FACT-LCS (Lung Cancer Subscale) percentage of clinically meaningful declines (CMD) were determined. A linear mixed-effects model was used to determine which patient, clinical, dose, and dose-function metrics were predictive of PRO decline. RESULTS: 59 patients completed baseline PRO surveys. 83% of patients had non-small-cell lung cancer, with 75% having stage III disease. The median dose was 60 Gy in 30 fractions. CMD FACT-TOI decline was 46.3%, 38.5%, and 26.8%, at 3, 6, and 12 months, respectively. CMD FACT-LCS decline was 33.3%, 33.3%, and 29.3%, at 3, 6, and 12 months, respectively. While an increase in most dose and dose-function parameters was associated with a modest decline in PROs, none of the results were significant (all p>0.053). CONCLUSION: The current work provides an innovative combination of functional avoidance and PROs and is the first report of PROs for patients treated with prospective 4DCT-ventilation functional avoidance. Approximately 30% of patients had clinically significant decline in PROs at 12 months. The study provides additional data on outcomes with 4DCT-ventilation functional avoidance.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38631538

RESUMO

PURPOSE: To provide an understanding of current FLI techniques, and their potential to improve dosimetry and outcomes for lung cancer patients receiving radiation therapy (RT). METHODS: EMBASE, PubMed, and Cochrane Library were searched from 1990 until April 2023. Articles were included if they reported on FLI in one of: techniques, incorporation into RT planning for lung cancer, quantification of RT-related outcomes for lung cancer patients. Studies involving all RT modalities, including stereotactic body radiotherapy and particle therapy, were included. Meta-analyses were conducted to investigate differences in dose-function parameters between anatomical and functional RT planning techniques, as well as to investigate correlations of dose-function parameters with grade 2+ radiation pneumonitis (RP). RESULTS: 178 studies were included in the narrative synthesis. We report on FLI modalities, dose-response quantification, functional lung (FL) definitions, FL avoidance techniques, and correlations between FL irradiation and toxicity. Meta-analysis results show that FL avoidance planning gives statistically significant absolute reductions of 3.22% to the fraction of well-ventilated lung receiving 20 Gy or more (vent-fV20), 3.52% to the fraction of well-perfused lung receiving 20 Gy or more (perf-fV20), 1.3 Gy to the mean dose to the well-ventilated lung (vent-fMLD), and 2.41 Gy to the mean dose to the well-perfused lung (perf-fMLD). Increases in the threshold value for defining FL are associated with decreases in functional parameters. For intensity-modulated radiation therapy and volumetric modulated arc therapy, avoidance planning results in a 13% rate of grade 2+ RP, which seems reduced compared to results from conventional planning cohorts. A trend of increased predictive ability for grade 2+ RP was seen in models using FL information, but was not statistically significant. CONCLUSIONS: FLI shows promise as a method to spare FL during thoracic RT, but interventional trials related to FL avoidance planning are sparse. Such trials are critical to understanding the impact of FL avoidance planning on toxicity reduction and patient outcomes.

3.
JCO Clin Cancer Inform ; 8: e2300241, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38452302

RESUMO

PURPOSE: Traditional methods of evaluating cardiotoxicity focus on radiation doses to the heart. Functional imaging has the potential to provide improved prediction for cardiotoxicity for patients with lung cancer. Fluorine-18 (18F) fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) imaging is routinely obtained in a standard cancer staging workup. This work aimed to develop a radiomics model predicting clinical cardiac assessment using 18F-FDG PET/CT scans before thoracic radiation therapy. METHODS: Pretreatment 18F-FDG PET/CT scans from three study populations (N = 100, N = 39, N = 70) were used, comprising two single-institutional protocols and one publicly available data set. A clinician (V.J.) classified the PET/CT scans per clinical cardiac guidelines as no uptake, diffuse uptake, or focal uptake. The heart was delineated, and 210 novel functional radiomics features were selected to classify cardiac FDG uptake patterns. Training data were divided into training (80%)/validation (20%) sets. Feature reduction was performed using the Wilcoxon test, hierarchical clustering, and recursive feature elimination. Ten-fold cross-validation was carried out for training, and the accuracy of the models to predict clinical cardiac assessment was reported. RESULTS: From 202 of 209 scans, cardiac FDG uptake was scored as no uptake (39.6%), diffuse uptake (25.3%), and focal uptake (35.1%), respectively. Sixty-two independent radiomics features were reduced to nine clinically pertinent features. The best model showed 93% predictive accuracy in the training data set and 80% and 92% predictive accuracy in two external validation data sets. CONCLUSION: This work used an extensive patient data set to develop a functional cardiac radiomic model from standard-of-care 18F-FDG PET/CT scans, showing good predictive accuracy. The radiomics model has the potential to provide an automated method to predict existing cardiac conditions and provide an early functional biomarker to identify patients at risk of developing cardiac complications after radiotherapy.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , 60570 , Cardiotoxicidade , Tomografia por Emissão de Pósitrons
4.
Pract Radiat Oncol ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38508451

RESUMO

PURPOSE: There have been numerous significant ransomware attacks impacting Radiation Oncology in the past 5 years. Research into ransomware attack response in Radiation Oncology has consisted of case reports and descriptive articles and has lacked quantitative studies. The purpose of this work was to identify the significant safety risks to patients being treated with radiation therapy during a ransomware attack scenario, using Failure Modes and Effects Analysis. METHODS AND MATERIALS: A multi-institutional and multidisciplinary team conducted a Failure Modes and Effects Analysis by developing process maps and using Risk Priority Number (RPN) scores to quantify the increased likelihood of incidents in a ransomware attack scenario. The situation that was simulated was a ransomware attack that had removed the capability to access the Record and Verify (R&V) system. Five situations were considered: 1) a standard treatment of a patient with and without an R&V, 2) a standard treatment of a patient for the first fraction right after the R&V capabilities are disabled, and 3) 3 situations in which a plan modification was required. RPN scores were compared with and without R&V functionality. RESULTS: The data indicate that RPN scores increased by 71% (range, 38%-96%) when R&V functionality is disabled compared with a nonransomware attack state where R&V functionality is available. The failure modes with the highest RPN in the simulated ransomware attack state included incorrectly identifying patients on treatment, incorrectly identifying where a patient is in their course of treatment, treating the incorrect patient, and incorrectly tracking delivered fractions. CONCLUSIONS: The presented study quantifies the increased risk of incidents when treating in a ransomware attack state, identifies key failure modes that should be prioritized when preparing for a ransomware attack, and provides data that can be used to guide future ransomware resiliency research.

5.
Br J Radiol ; 97(1155): 660-667, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38401536

RESUMO

OBJECTIVES: To evaluate patient-specific quality assurance (PSQA) of 3 targets in a single delivery using a novel film-based phantom. METHODS: The phantom was designed to rotate freely as a sphere and could measure 3 targets with film in a single delivery. After identifying the coordinates of 3 targets in the skull, the rotation angles about the equator and meridian were computed for optimal phantom setup, ensuring the film plane intersected the 3 targets. The plans were delivered on the CyberKnife system using fiducial tracking. The irradiated films were scanned and processed. All films were analysed using 3 gamma criteria. RESULTS: Fifteen CyberKnife test plans with 3 different modalities were delivered on the phantom. Both automatic and marker-based registration methods were applied when registering the irradiated film and dose plane. Gamma analysis was performed using a 3%/1 mm, 2%/1 mm, and 1%/1 mm criteria with a 10% threshold. For the automatic registration method, the passing rates were 98.2% ± 1.9%, 94.2% ± 3.7%, and 80.9% ± 6.3%, respectively. For the marker-based registration approach, the passing rates were 96.4% ± 2.7%, 91.7% ± 4.3%, and 78.4% ± 6.2%, respectively. CONCLUSIONS: A novel spherical phantom was evaluated for the CyberKnife system and achieved acceptable PSQA passing rates using TG218 recommendations. The phantom can measure true-composite dose and offers high-resolution results for PSQA, making it a valuable device for robotic radiosurgery. ADVANCES IN KNOWLEDGE: This is the first study on PSQA of 3 targets concurrently on the CyberKnife system.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Procedimentos Cirúrgicos Robóticos , Humanos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos
6.
Adv Radiat Oncol ; 9(3): 101409, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38298328

RESUMO

Purpose: Positional errors resulting from motion are a principal challenge across all disease sites in radiation therapy. This is particularly pertinent when treating lesions in the liver with stereotactic body radiation therapy (SBRT). To achieve dose escalation and margin reduction for liver SBRT, kV real-time imaging interventions may serve as a potential solution. In this study, we report results of a retrospective cohort of liver patients treated using real-time 2D kV-image guidance SBRT with emphasis on the impact of (1) clinical workflow, (2) treatment accuracy, and (3) tumor dose. Methods and Materials: Data from 33 patients treated with 41 courses of liver SBRT were analyzed. During treatment, planar kV images orthogonal to the treatment beam were acquired to determine treatment interventions, namely treatment pauses (ie, adequacy of gating thresholds) or treatment shifts. Patients were shifted if internal markers were >3 mm, corresponding to the PTV margin used, from the expected reference condition. The frequency, duration, and nature of treatment interventions (ie, pause vs shift) were recorded, and the dosimetric impact associated with treatment shifts was estimated using a machine learning dosimetric model. Results: Of all fractions delivered, 39% required intervention, which took on average 1.9 ± 1.6 minutes and occurred more frequently in treatments lasting longer than 7 minutes. The median realignment shift was 5.7 mm in size, and the effect of these shifts on minimum tumor dose in simulated clinical scenarios ranged from 0% to 50% of prescription dose per fraction. Conclusion: Real-time kV-based imaging interventions for liver SBRT minimally affect clinical workflow and dosimetrically benefit patients. This potential solution for addressing positional errors from motion addresses concerns about target accuracy and may enable safe dose escalation and margin reduction in the context of liver SBRT.

7.
Int J Radiat Oncol Biol Phys ; 118(1): 242-252, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37607642

RESUMO

PURPOSE: A novel form of lung functional imaging applied for functional avoidance radiation therapy has been developed that uses 4-dimensional computed tomography (4DCT) data and image processing techniques to calculate lung ventilation (4DCT-ventilation). Lung segmentation is a common step to define a region of interest for 4DCT-ventilation generation. The purpose of this study was to quantitatively evaluate the sensitivity of 4DCT-ventilation imaging using different lung segmentation methods. METHODS AND MATERIALS: The 4DCT data of 350 patients from 2 institutions were used. Lung contours were generated using 3 methods: (1) reference segmentations that removed airways and pulmonary vasculature manually (Lung-Manual), (2) standard lung contours used for planning (Lung-RadOnc), and (3) artificial intelligence (AI)-based contours that removed the airways and pulmonary vasculature (Lung-AI). The AI model was based on a residual 3-dimensional U-Net and was trained using the Lung-Manual contours of 279 patients. We compared the Lung-RadOnc or Lung-AI with Lung-Manual contours for the entire 4DCT-ventilation functional avoidance process including lung segmentation (surface Dice similarity coefficient [Surface DSC]), 4DCT-ventilation generation (correlation), and subanalysis of 10 patients on a dosimetric endpoint (percentage of high functional volume of lung receiving ≥20 Gy [fV20{%}]). RESULTS: Surface DSC comparing Lung-Manual/Lung-RadOnc and Lung-Manual/Lung-AI contours was 0.40 ± 0.06 and 0.86 ± 0.04, respectively. The correlation between 4DCT-ventilation images generated with Lung-Manual/Lung-RadOnc and Lung-Manual/Lung-AI were 0.48 ± 0.14 and 0.85 ± 0.14, respectively. The difference in fV20[%] between 4DCT-ventilation generated with Lung-Manual/Lung-RadOnc and Lung-Manual/Lung-AI was 2.5% ± 4.1% and 0.3% ± 0.5%, respectively. CONCLUSIONS: Our work showed that using standard planning lung contours can result in significantly variable 4DCT-ventilation images. The study demonstrated that AI-based segmentations generate lung contours and 4DCT-ventilation images that are similar to those generated using manual methods. The significance of the study is that it characterizes the lung segmentation sensitivity of the 4DCT-ventilation process and develops methods that can facilitate the integration of this novel imaging in busy clinics.


Assuntos
Neoplasias Pulmonares , Ventilação Pulmonar , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Inteligência Artificial , Pulmão/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional/métodos
8.
Radiother Oncol ; 187: 109821, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37516361

RESUMO

PURPOSE: Functional avoidance radiotherapy uses functional imaging to reduce pulmonary toxicity by designing radiotherapy plans that reduce doses to functional regions of the lung. A phase-II, multi-center, prospective study of 4DCT-ventilation functional avoidance was completed. Pre and post-treatment pulmonary function tests (PFTs) were acquired and assessed pulmonary function change. This study aims to evaluate which clinical, dose and dose-function factors predict PFT changes for patients treated with 4DCT-ventilation functional avoidance radiotherapy. MATERIALS AND METHODS: 56 patients with locally advanced lung cancer receiving radiotherapy were accrued. PFTs were obtained at baseline and three months following radiotherapy and included forced expiratory volume in 1-second (FEV1), forced vital capacity (FVC), and FEV1/FVC. The ability of patient, clinical, dose (lung and heart), and dose-function metrics (metrics that combine dose and 4DCT-ventilation-based function) to predict PFT changes were evaluated using univariate and multivariate linear regression. RESULTS: Univariate analysis showed that only dose-function metrics and the presence of chronic obstructive pulmonary disease (COPD) were significant (p<0.05) in predicting FEV1 decline. Multivariate analysis identified a combination of clinical (immunotherapy status, presence of thoracic comorbidities, smoking status, and age), along with lung dose, heart dose, and dose-function metrics in predicting FEV1 and FEV1/FVC changes. CONCLUSION: The current work evaluated factors predicting PFT changes for patients treated in a prospective functional avoidance radiotherapy study. The data revealed that lung dose- function metrics could predict PFT changes, validating the significance of reducing the dose to the functional lung to mitigate the decline in pulmonary function and providing guidance for future clinical trials.


Assuntos
Neoplasias Pulmonares , Pulmão , Humanos , Neoplasias Pulmonares/radioterapia , Estudos Prospectivos , Respiração , Testes de Função Respiratória
9.
Int J Radiat Oncol Biol Phys ; 117(1): 53-63, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36918130

RESUMO

PURPOSE: The optimal dose and fractionation of stereotactic body radiation therapy (SBRT) for locally advanced pancreatic cancer (LAPC) have not been defined. Single-fraction SBRT was associated with more gastrointestinal toxicity, so 5-fraction regimens have become more commonly employed. We aimed to determine the safety and maximally tolerated dose of 3-fraction SBRT for LAPC. METHODS AND MATERIALS: Two parallel phase 1 dose escalation trials were conducted from 2016 to 2019 at Memorial Sloan Kettering Cancer Center and University of Colorado. Patients with histologically confirmed LAPC without distant progression after at least 2 months of induction chemotherapy were eligible. Patients received 3-fraction linear accelerator-based SBRT at 3 dose levels, 27, 30, and 33 Gy, following a modified 3+3 design. Dose-limiting toxicity, defined as grade ≥3 gastrointestinal toxicity within 90 days, was scored by National Cancer Institute Common Terminology Criteria for Adverse Events, version 4. The secondary endpoints included cumulative incidence of local failure (LF) and distant metastasis (DM), as well as progression-free and overall survival PFS and OS, respectively, toxicity, and quality of life (QoL) using the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire (QLQ-C30) and the pancreatic cancer-specific QLQ-PAN26 questionnaire. RESULTS: Twenty-four consecutive patients were enrolled (27 Gy: 9, 30 Gy: 8, 33 Gy: 7). The median (range) age was 67 (52-79) years, and 12 (50%) had a head/uncinate tumor location, with a median tumor size of 3.8 (1.1-11) cm and CA19-9 of 60 (1-4880) U/mL. All received chemotherapy for a median of 4 (1.4-10) months. There were no grade ≥3 toxicities. Two-year rates (95% confidence interval) of LF, DM, PFS, and OS were 31.7% (8.6%-54.8%), 70.2% (49.7%-90.8%), 20.8% (4.6%-37.1%), and 29.2% (11.0%-47.4%), respectively. Three- and 6-month QoL assessment showed no detriment. CONCLUSIONS: For select patients with LAPC, dose escalation to 33 Gy in 3 fractions resulted in no dose-limiting toxicities, no detriments to QoL, and disease outcomes comparable with conventional RT. Further exploration of SBRT schemes to maximize tumor control while enabling efficient integration with systemic therapy is warranted.


Assuntos
Segunda Neoplasia Primária , Neoplasias Pancreáticas , Radiocirurgia , Humanos , Idoso , Qualidade de Vida , Radiocirurgia/efeitos adversos , Pâncreas , Neoplasias Pancreáticas/radioterapia
10.
Adv Radiat Oncol ; 8(2): 101133, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36618762

RESUMO

Purpose: Four-dimensional computed tomography (4DCT)-ventilation-based functional avoidance uses 4DCT images to generate plans that avoid functional regions of the lung with the goal of reducing pulmonary toxic effects. A phase 2, multicenter, prospective study was completed to evaluate 4DCT-ventilation functional avoidance radiation therapy. The purpose of this study was to report the results for pretreatment to posttreatment pulmonary function test (PFT) changes for patients treated with functional avoidance radiation therapy. Methods and Materials: Patients with locally advanced lung cancer receiving chemoradiation were accrued. Functional avoidance plans based on 4DCT-ventilation images were generated. PFTs were obtained at baseline and 3 months after chemoradiation. Differences for PFT metrics are reported, including diffusing capacity for carbon monoxide (DLCO), forced expiratory volume in 1 second (FEV1), and forced vital capacity (FVC). PFT metrics were compared for patients who did and did not experience grade 2 or higher pneumonitis. Results: Fifty-six patients enrolled on the study had baseline and posttreatment PFTs evaluable for analysis. The mean change in DLCO, FEV1, and FVC was -11.6% ± 14.2%, -5.6% ± 16.9%, and -9.0% ± 20.1%, respectively. The mean change in DLCO was -15.4% ± 14.4% for patients with grade 2 or higher radiation pneumonitis and -10.8% ± 14.1% for patients with grade <2 radiation pneumonitis (P = .37). The mean change in FEV1 was -14.3% ± 22.1% for patients with grade 2 or higher radiation pneumonitis and -3.9% ± 15.4% for patients with grade <2 radiation pneumonitis (P = .09). Conclusions: The current work is the first to quantitatively characterize PFT changes for patients with lung cancer treated on a prospective functional avoidance radiation therapy study. In comparison with patients treated with standard thoracic radiation planning, the data qualitatively show that functional avoidance resulted in less of a decline in DLCO and FEV1. The presented data can help elucidate the potential pulmonary function improvement with functional avoidance radiation therapy.

11.
Br J Radiol ; 96(1143): 20220119, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36633096

RESUMO

OBJECTIVE: Current ventilation and perfusion dose-response studies focus on single-modalities (ventilation or perfusion) and perform pulmonary-toxicity assessment related to radiotherapy on a population-based basis. This study aims at quantitative and clinical evaluation of intrapatient differences between ventilation and perfusion dose-responses among lung cancer patients treated with radiotherapy. METHODS: 20 patients enrolled on a prospective functional avoidance protocol underwent single photon emission computed tomography-CT ventilation and perfusion scans pre- and post-radiotherapy. Relative changes in pre- to post-treatment ventilation and perfusion in lung regions receiving ≥20 Gy were calculated. In addition, the slopes of the linear fit to the relative ventilation and perfusion changes in regions receiving 0-60 Gy were calculated. A radiologist read and assigned a functional defect score to pre- and post-treatment ventilation/perfusion scans. RESULTS: 25% of patients had a difference >35% between ventilation and perfusion pre- to post-treatment changes and 20-30% of patients had opposite directions for ventilation and perfusion pre- to post-treatment changes. Using a semi-quantitative scale, radiologist assessment showed that 20% of patients had different pre- to post-treatment ventilation changes when compared to pre- to post-treatment perfusion changes. CONCLUSION: Our data showed that ventilation dose-response can differ from perfusion dose-response for 20-30% of patients. Therefore, when performing thoracic dose-response in cancer patients, it is insufficient to look at ventilation or perfusion alone; but rather both modes of functional imaging may be needed when predicting for clinical outcomes. ADVANCES IN KNOWLEDGE: The significance of this study can be highlighted by the differences between the intrapatient dose-response assessments of this analysis compared to existing population-based dose-response analyses. Elucidating intrapatient ventilation and perfusion dose-response differences may be valuable in predicting pulmonary toxicity in lung cancer patients post-radiotherapy.


Assuntos
Pneumopatias , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Estudos Prospectivos , Pulmão , Respiração , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Perfusão
12.
J Appl Clin Med Phys ; 24(9): e13552, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35243772

RESUMO

PURPOSE: Heart doses have been shown to be predictive of cardiac toxicity and overall survival (OS) for esophageal cancer patients. There is potential for functional imaging to provide valuable cardiac information. The purpose of this study was to evaluate the cardiac metabolic dose-response using 18 F-deoxyglucose (FDG)-PET and to assess whether standard uptake value (SUV) changes in the heart were predictive of OS. METHODS: Fifty-one patients with esophageal cancer treated with radiation who underwent pre- and post-treatment FDG-PET scans were retrospectively evaluated. Pre- and post-treatment PET-scans were rigidly registered to the planning CT for each patient. Pre-treatment to post-treatment absolute mean SUV (SUVmean) changes in the heart were calculated to assess dose-response. A dose-response curve was generated by binning each voxel in the heart into 10 Gy dose-bins and analyzing the SUVmean changes in each dose-bin. Multivariate cox proportional hazard models were used to assess whether pre-to-post treatment cardiac SUVmean changes predicted for OS. RESULTS: The cardiac dose-response curve demonstrated a trend of increasing cardiac SUV changes as a function of dose with an average increase of 0.044 SUV for every 10 Gy dose bin. In multivariate analysis, disease stage and SUVmean change in the heart were predictive (p < 0.05) for OS. CONCLUSIONS: Changes in pre- to post-treatment cardiac SUV were predictive of OS with patients having a higher pre- to post-treatment cardiac SUV change surviving longer.


Assuntos
Neoplasias Esofágicas , Fluordesoxiglucose F18 , Humanos , Fluordesoxiglucose F18/metabolismo , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/radioterapia , Coração/diagnóstico por imagem , Compostos Radiofarmacêuticos
13.
Radiother Oncol ; 171: 22-24, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35413391

RESUMO

The purpose of this work was to use data from a large co-operative group trial to evaluate whether metabolic FDG-PET changes in the heart for lung cancer patients can predict for clinical outcomes. The study found that cardiac SUV changes following definitive chemoradiation are significantly (HR 0.811, 95% CI 0.68-0.96, p = 0.017) associated with overall survival in locally advanced NSCLC patients. If validated in a prospective cohort, our data show the potential for cardiac metabolic changes to be an early predictor for clinical outcomes.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma Pulmonar de Células não Pequenas/terapia , Quimiorradioterapia , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/terapia , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Compostos Radiofarmacêuticos
14.
Front Oncol ; 12: 842579, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35359361

RESUMO

Purpose: Spine SBRT target delineation is time-consuming due to the complex bone structure. Recently, Elements SmartBrush Spine (ESS) was developed by Brainlab to automatically generate a clinical target volume (CTV) based on gross tumor volume (GTV). The aim of this project is to evaluate the accuracy and efficiency of ESS auto-segmentation. Methods: Twenty spine SBRT patients with 21 target sites treated at our institution were used for this retrospective comparison study. Planning CT/MRI images and physician-drawn GTVs were inputs for ESS. ESS can automatically segment the vertebra, split the vertebra into 6 sectors, and generate a CTV based on the GTV location, according to the International Spine Radiosurgery Consortium (ISRC) Consensus guidelines. The auto-segmented CTV can be edited by including/excluding sectors of the vertebra, if necessary. The ESS-generated CTV contour was then compared to the clinically used CTV using qualitative and quantitative methods. The CTV contours were compared using visual assessment by the clinicians, relative volume differences (RVD), distance of center of mass (DCM), and three other common contour similarity measurements such as dice similarity coefficient (DICE), Hausdorff distance (HD), and 95% Hausdorff distance (HD95). Results: Qualitatively, the study showed that ESS can segment vertebra more accurately and consistently than humans at normal curvature conditions. The accuracy of CTV delineation can be improved significantly if the auto-segmentation is used as the first step. Conversely, ESS may mistakenly split or join different vertebrae when large curvatures in anatomy exist. In this study, human interactions were needed in 7 of 21 cases to generate the final CTVs by including/excluding sectors of the vertebra. In 90% of cases, the RVD were within ±15%. The RVD, DCM, DICE, HD, and HD95 for the 21 cases were 3% ± 12%, 1.9 ± 1.5 mm, 0.86 ± 0.06, 13.34 ± 7.47 mm, and 4.67 ± 2.21 mm, respectively. Conclusion: ESS can auto-segment a CTV quickly and accurately and has a good agreement with clinically used CTV. Inter-person variation and contouring time can be reduced with ESS. Physician editing is needed for some occasions. Our study supports the idea of using ESS as the first step for spine SBRT target delineation to improve the contouring consistency as well as to reduce the contouring time.

15.
Pract Radiat Oncol ; 12(4): e253-e268, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35283342

RESUMO

PURPOSE: This updated report on stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) is part of a series of consensus-based white papers previously published addressing patient safety. Since the first white papers were published, SRS and SBRT technology and procedures have progressed significantly such that these procedures are now more commonly used. The complexity and submillimeter accuracy, and delivery of a higher dose per fraction requires an emphasis on best practices for technical, dosimetric, and quality assurance. Therefore, quality and patient safety considerations for these techniques remain an important area of focus. METHOD: The American Society for Radiation Oncology convened a task force to assess the original SRS/SBRT white paper and update content where appropriate. Recommendations were created using a consensus-building methodology and task force members indicated their level of agreement based on a 5-point Likert scale, from "strongly agree" to "strongly disagree." A prespecified threshold of ≥75% of raters who select "strongly agree" or "agree" indicated consensus. SUMMARY: This white paper builds on the previous version and uses of other guidance documents to broadly address SRS and SBRT delivery, primarily focusing on processes related to quality and safety. SRS and SBRT require a team-based approach, staffed by appropriately trained and credentialed specialists as well as significant personnel resources, specialized technology, and implementation time. A thorough feasibility analysis of resources is required to achieve the clinical and technical goals and thoroughly discussed with all personnel before undertaking new disease sites. A comprehensive quality assurance program must be developed, using established treatment guidelines, to ensure SRS and SBRT are performed in a safe and effective manner. Patient safety in SRS/SBRT is everyone's responsibility and professional organizations, regulators, vendors, and end-users must demonstrate a clear commitment to working together to ensure the highest levels of safety.


Assuntos
Radioterapia (Especialidade) , Radiocirurgia , Consenso , Humanos , Radiometria , Radiocirurgia/métodos
16.
Int J Radiat Oncol Biol Phys ; 112(4): 986-995, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-34767934

RESUMO

PURPOSE: Radiation pneumonitis remains a major limitation in the radiation therapy treatment of patients with lung cancer. Functional avoidance radiation therapy uses functional imaging to reduce pulmonary toxic effects by designing radiation therapy plans that reduce doses to functional regions of the lung. Lung functional imaging has been developed that uses 4-dimensional computed tomography (4DCT) imaging to calculate 4DCT-based lung ventilation (4DCT-ventilation). A phase 2 multicenter study was initiated to evaluate 4DCT-ventilation functional avoidance radiation therapy. The study hypothesis was that functional avoidance radiation therapy could reduce the rate of grade ≥2 radiation pneumonitis to 12% compared with a 25% historical rate, with the trial being positive if ≤16.4% of patients experienced grade ≥2 pneumonitis. METHODS AND MATERIALS: Lung cancer patients receiving curative-intent radiation therapy (prescription doses of 45-75 Gy) and chemotherapy were accrued. Patient 4DCT scans were used to generate 4DCT-ventilation images. The 4DCT-ventilation images were used to generate functional avoidance plans that reduced doses to functional portions of the lung while delivering the prescribed tumor dose. Pneumonitis was evaluated by a clinician at 3, 6, and 12 months after radiation therapy. RESULTS: Sixty-seven evaluable patients were accrued between April 2015 and December 2019. The median prescription dose was 60 Gy (range, 45-66 Gy) delivered in 30 fractions (range, 15-33 fractions). The average reduction in the functional volume of lung receiving ≥20 Gy with functional avoidance was 3.5% (range, 0%-12.8%). The median follow-up was 312 days. The rate of grade ≥2 radiation pneumonitis was 10 of 67 patients (14.9%; 95% upper CI, 24.0%), meeting the phase 2 criteria. CONCLUSIONS: 4DCT-ventilation offers an imaging modality that is convenient and provides functional imaging without an extra procedure necessary. This first report of a multicenter study of 4DCT-ventilation functional avoidance radiation therapy provided data showing that the trial met phase 2 criteria and that evaluation in a phase 3 study is warranted.


Assuntos
Neoplasias Pulmonares , Pneumonite por Radiação , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Ventilação Pulmonar/efeitos da radiação , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/prevenção & controle , Planejamento da Radioterapia Assistida por Computador/métodos
17.
Pract Radiat Oncol ; 12(2): 170-174, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34644601

RESUMO

The digitization of healthcare for patient safety and efficiency introduced third party networks into closed hospital systems increasing the probability of cyberattacks and their consequences(1). In April 2021, a major vendor of a Radiation Oncology (RO) record and verify system (RVS) suffered a ransomware attack, affecting our department and many others across the United States. This article summarizes our response to the ransomware event including workflows, team member roles, responsibilities, communications and departmental recovery. The RVS created or housed accurate patient dose records for 6 locations. The immediate response to the ransomware attack was to shut down the system including the ability to treat patients. With the utilization of the hospital EMR and pre-existing interfaces with RVS, the department was able to safely continue patient radiotherapy treatments innovatively utilizing a direct Digital Imaging and Communications in Medicine (DICOM) transfer of patient data to the linear accelerators and implementing paper charting. No patients were treated in the first 24 hours of the attack. Within 48 hours of the ransomware event, 50% of patients were treated, and within 1 week, 95% of all patients were treated using direct DICOM transfer and paper charts. The RVS was completely unavailable for 2.5 weeks and full functionality was not restored for 4.5 weeks. A phased approach was adopted for re-introduction of patient treatments back into the RVS. Human capital costs included communication, outreach, workflow creation, quality assurance and extended clinical hours. Key lessons learned were to have a back-up of essential information, employ 'dry run' emergency training, having consistent parameter requirements across different vendor hardware and software, and having a plan for the recovery effort of restoring normal operations once software is operational. The provided report presents valuable information for the development of cyber-attack preparedness for RO departments.


Assuntos
Radioterapia (Especialidade) , Comunicação , Atenção à Saúde , Humanos , Aceleradores de Partículas , Estados Unidos , Fluxo de Trabalho
18.
J Appl Clin Med Phys ; 22(7): 276-285, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34159715

RESUMO

The primary objective is to evaluate the potential dosimetric gains of performing functional avoidance-based proton treatment planning using 4DCT derived ventilation imaging. 4DCT data of 31 patients from a prospective functional avoidance clinical trial were evaluated with intensity modulated proton therapy (IMPT) plans and compared with clinical volumetric modulated arc therapy (VMAT) plans. Dosimetric parameters were compared between standard and functional plans with IMPT and VMAT with one-way analysis of variance and post hoc paired student t-test. Normal Tissue Complication Probability (NTCP) models were employed to estimate the risk of two toxicity endpoints for healthy lung tissues. Dose degradation due to proton motion interplay effect was evaluated. Functional IMPT plans led to significant dose reduction to functional lung structures when compared with functional VMAT without significant dose increase to Organ at Risk (OAR) structures. When interplay effect is considered, no significant dose degradation was observed for the OARs or the clinical target volume (CTV) volumes for functional IMPT. Using fV20 as the dose metric and Grade 2+ pneumonitis as toxicity endpoint, there is a mean 5.7% reduction in Grade 2+ RP with the functional IMPT and as high as 26% in reduction for individual patient when compared to the standard IMPT planning. Functional IMPT was able to spare healthy lung tissue to avoid excess dose to normal structures while maintaining satisfying target coverage. NTCP calculation also shows that the risk of pulmonary complications can be further reduced with functional based IMPT.


Assuntos
Neoplasias Pulmonares , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Órgãos em Risco , Estudos Prospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
20.
Radiother Oncol ; 160: 120-124, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33964328

RESUMO

This study investigates agreement between ventilation and perfusion for lung cancer patients undergoing radiotherapy. Ventilation-perfusion scans of nineteen patients with stage III lung cancer from a prospective protocol were compared using voxel-wise Spearman correlation-coefficients. The presented results show in about 25% of patients, ventilation and perfusion exhibit lower agreement.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Perfusão , Estudos Prospectivos , Ventilação Pulmonar , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...